CGNHM - PAINT STRIPPER #4

Product Identification

Product ID:PAINT STRIPPER #4
MSDS Date:05/01/1991
FSC:8010
NIIN:00-943-7128
MSDS Number: CGNHM

Responsible Party
CREST INDUSTRIAL CHEMICALS INC
6341 BEVERLY HILL
HOUSTON, TX 77242
US

Emergency Phone: 800-255-3924

Info Phone: 713-780-8169

Cage: 77513

Contractor
CREST INDUSTRIAL CHEMICALS INC
42242 HOUSTON, TX 77057-6500 US

Telephone: 713-780-1828

Cage: 77513

Ingredients

METHLENE CHLORIDE

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

OSHA PEL 400 PPM

ACGIH TLV: 500 PPM


TOLUENE (SARA III) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SODIUM CHROMATE (SARA 313) (CERCLA)

CAS: 7775-11-3

RTECS: GB2955000

OSHA PEL 0.05 MG/M3

ACGIH TLV: 0.05 PPM

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


AQUEOUS AMMONIA (CERCLA)

CAS: 1336-21-6

RTECS: BQ9625000

OSHA PEL 20 PPM

ACGIH TLV: 25 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATION. SKIN: DERMITITUS.
INHAL: IRRITATION TO NOSE, NARCOSIS, DIZZY, LIGHTHEADEDNESS.
Explanation of Carcinogenicity:SODIUM CHROMATE >1%. IS NOT BELIEVED TO
POSE A MEASURABLE CARCINOGENIC WHEN HANDLED & USED AS RECOMMENDED.

First Aid

First Aid:EYE: FLUSH WITH WATER. GET MEDICAL ATTENTION. SKIN: WASH WITH
SOAP AND WATER. INHAL: GET FRESH AIR.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE TO BOIL
Extinguishing Media:CARBON DIOXIDE, CHEMICAL FOAM OR WATER SPRAY.
Fire Fighting Procedures:USE PRESSURE DEMAND, SCBA. USE WATER SPRAY TO
COOL CONTAINERS.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION WILL PRODUCE TOXIC
OXIDES OF CHLORINE.

Accidental Release

Spill Release Procedures:VENTILATE AREA. MOP UP SPILLAGE. CONTAIN AS
NECESSARY. TRANSFER TO CLOSED METAL CONTAINERS. DONT DUMP INTO
SEWERS, ON THE GROUND OR ANY BODY OF WATER.

Handling

Handling and Storage Precautions:DONT STORE BELOW 80F. DONT STORE IN
DIRECT SUNLIGHT.
Other Precautions:CONTENTS MAY BE UNDER PRESSURE IN STORAGE. OPEN
CAUTIOSLY TO AVOID INJURY.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED FRESH AIR MASK.
Ventilation:MECHANICAL (GENERAL) OR LOCAL EXHAUST.
Protective Gloves:SLOVENT RESISTANT GLOVES.
Eye Protection:CHEM SAFETY GLASSES & FULL FACE SHIELD.
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:WASH HANDS & FACE WITH SOAP & WATER BEFORE
SMOKING OR EATING.
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:108F,42C
Melt/Freeze Pt:M.P/F.P Text:NA
Vapor Pres:360 MM HG
Vapor Density:>1
Spec Gravity:1.02
Evaporation Rate & Reference:1
Solubility in Water:PARTIALLY
Appearance and Odor:VISCOUS YELLOW LIQUID, AMMONIA ODOR

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STRONG OXIDIZERS AND MINERAL ACIDS.
Hazardous Decomposition Products:CARBON DIOXIDE AND OXIDES OF CHLOINE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE,
AND FEDERAL REGULATIONS. APPROPRIATE DISPOSAL SHOULD BE DONE BY A
COMPETENT AND PROPERLY PERMITTED CONTRATOR.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.